Simvol
|
XUShMATLAR
|
Sinov sharoitlari
|
Tj( 。C) |
Qiymat |
Бирлик
|
Min |
TUR |
Maksimal |
IT(AV) |
O'rtacha yoqilgan holatdagi tok |
180。yarim sinus to'lqini 50Hz Ikki tomonlama sovutilgan, |
TC=55 。C |
125 |
|
|
900 |
A |
VDRM VRRM |
Takroriy pik off-holati kuchlanishi Takroriy pik orqaga kuchlanishi |
tp=10ms |
125 |
1200 |
|
1600 |
V |
Idrm Irrm |
Takrorlanuvchi yuqori o'zgarish oqimi Takrorlanuvchi yuqori o'zgarish oqimi |
vDRM va VRRM da |
125 |
|
|
50 |
mA |
ITSM |
To'lqin yoqilgan holatdagi tok |
10ms yarm sine to'lqini VR=0.6VRRM |
125 |
|
|
10 |
kA |
I2t |
Qayta birikish uchun I2t |
|
|
500 |
A2s*103 |
VTO |
Chiziqli kuchlanishni |
|
125
|
|
|
1.70 |
V |
rt |
Yoqilgan holatdagi qiyshiq qarshilik |
|
|
0.48 |
mΩ |
VTM |
Eng yuqori yoqilgan holatdagi kuchlanish |
ITM=1500A, F=18kN |
25 |
|
|
3.15 |
V |
dv/dt |
O'chirilgan holat voltajining tanqidiy ko'tarilish tezligi |
VDM=0.67VDRM |
125 |
|
|
1000 |
V/μs |
di/dt |
O'rnatilgan holatdagi oqimning o'sishining kritik darajasi |
VDM= 67% VDRMdan 1600A gacha
Gate impuls tr ≤0.5μs IGM=1.5A
|
125 |
|
|
1500 |
A/μs |
Qrr |
Qaytarib olish haqi |
ITM=1000A, tp=4000µs, di/dt=-20A/µs, VR=100V |
125 |
|
33 |
50 |
µC |
tq |
O'zaro o'zgartirilgan o'chirish vaqti |
ITM=1000A, tp=4000μs, VR=100V dv/dt=30V/μs, di/dt=-20A/μs |
125 |
18 |
|
36 |
µs |
IGT |
Eshikni ishga tushirish tok |
VA=12V, IA=1A
|
25
|
30 |
|
250 |
mA |
Vgt |
Eshikni ishga tushirish kuchlanishi |
0.8 |
|
3.0 |
V |
IH |
Ushlab turish toki |
20 |
|
400 |
mA |
IL |
Qayta ushlab turish toki |
|
|
500 |
mA |
VGD |
Ishga tushirilmagan eshik kuchlanishi |
VDM=67%VDRM |
125 |
|
|
0.3 |
V |
Rth(j-c) |
Termal qarshilik kesishdan qutiga |
1800 sinusda, ikki tomonlama sovutilgan, Qisqarish kuchi 18kN |
|
|
|
0.028 |
。C /W
|
Rth(c-h) |
Termal qarshilik korpusdan issiqlik chiqaruvchiga |
|
|
|
0.0075 |
Fm |
O'rnatish kuchi |
|
|
15 |
|
20 |
kN |
Tvj |
Junction harorati |
|
|
-40 |
|
125 |
。C |
TSTG |
Saqlash harorati |
|
|
-40 |
|
140 |
。C |
Wt |
Og'irlik |
|
|
|
320 |
|
g |
Koʻrinish |
KT39cT40 |