6500V 250A
Pengenalan Ringkas:
Modul IGBT voltan tinggi, tunggal yang dihasilkan oleh CRRC. 6500V 250A .
Ciri-ciri
Tipikal pERMOHONAN
Nilai Nomer Maksimum
| Parameter | Simbol | Syarat | min | max | Unit | ||
| Kolektor-Pemancar voltan | V CES | V GE =0V,T vj ≥ 25°C | 
 | 6500 | V | ||
| Arus kolektor DC | Saya C | T C =80°C | 
 | 250 | A | ||
| Arus puncak kolektor | Saya CM | tp=1ms,Tc=80°C | 
 | 500 | A | ||
| Voltan penyiaran pintu | V GES | 
 | -20 | 20 | V | ||
| Kuasa keseluruhan perosakan | P tot | T C =25°C,perswitch(IGBT) | 
 | 3200 | W | ||
| Arus Maju DC | Saya F | 
 | 
 | 250 | A | ||
| Puncak ke hadapan semasa | Saya Pendapatan | tP=1ms | 
 | 500 | A | ||
| Pendek IGBT lITUPAN SOA | 
 t psc | V CC =4400V,V CEMCHIP ≤ 6500V V GE ≤ 15V,Tvj≤ 125°C | 
 | 
 10 | 
 μ s | ||
| Voltan pengasingan | V isolasi | 1min, f=50Hz | 
 | 10200 | V | ||
| Suhu persimpangan | T vj | 
 | 
 | 125 | ℃ | ||
| Suhu operasi sambungan | T vj(op) | 
 | -50 | 125 | ℃ | ||
| Suhu kes | T C | 
 | -50 | 125 | ℃ | ||
| Suhu penyimpanan | T sTG | 
 | -50 | 125 | ℃ | ||
| Tork pemasangan | Ms | 
 | 4 | 6 | Nm | ||
| M T1 | 
 | 8 | 10 | ||||
Nilai ciri IGBT
| Parameter | Simbol | Syarat | Min | tAIP | max | Unit | ||
| Kolektor (- pemancar) voltan pecahan | 
 V ((BR) CES | VGE=0V,IC=3mA, Tvj=25°C | 
 6500 | 
 | 
 | 
 V | ||
| Kolektor-Pemancar tepu voltan | VCEsat | IC=250A,V GE=15V | Tvj= 25°C | 2.6 | 3 | 3.4 | V | |
| Tvj=125°C | 3.4 | 4 | 4.6 | V | ||||
| Kolektor arus pemotongan | ICES | VCE=6500V,VGE=0V | Tvj= 25°C | 
 | 
 | 4 | mA | |
| Tvj=125°C | 
 | 
 | 50 | mA | ||||
| Pintu arus kebocoran | IGES | VCE=0V,VGE=20V,Tvj=125°C | -500 | 
 | 500 | nA | ||
| Ambang Gate-Emitter voltan | V GE (th) | IC=80mA,VCE=VGE,Tvj=25°C | 5.4 | 6.2 | 7 | V | ||
| Masa kelewatan penyambutan | t d (dalam) | 
 
 VCC=3600V, IC=250A, RGon=6.8Ω , RGoff=33Ω , CGE=100nF VGE=±15V, Ls=280nH, 感性负载 | TVj = 25 °C | 
 | 1 | 
 | 
 
 μ s | |
| TVj = 125 °C | 
 | 0.94 | 
 | |||||
| Kenaikan masa | tr | TVj = 25 °C | 
 | 0.76 | 
 | |||
| TVj = 125 °C | 
 | 0.81 | 
 | |||||
| Masa kelewatan penutupan | t d (((off) | TVj = 25 °C | 
 | 3.9 | 
 | 
 
 μ s | ||
| TVj = 125 °C | 
 | 4.2 | 
 | |||||
| Waktu kejatuhan | t f | TVj = 25 °C | 
 | 2.2 | 
 | |||
| TVj = 125 °C | 
 | 2.8 | 
 | |||||
| Penghidupan Suis tenaga hilang | EON | TVj = 25 °C | 
 | 3081 | 
 | mJ | ||
| TVj = 125 °C | 
 | 3900 | 
 | |||||
| Pemadaman Suis tenaga hilang | E dimatikan | TVj = 25 °C | 
 | 2100 | 
 | mJ | ||
| TVj = 125 °C | 
 | 1236 | 
 | |||||
| Pendek arus litar | 
 Saya SC | tpsc ≤ 10μ s, V GE =15V, Tvj=125℃,V CC = 4400V | 
 TVj = 125 °C | 
 | 
 940 | 
 | 
 A | |

Pasukan jualan profesional kami menunggu untuk berunding dengan anda. 
Anda boleh mengikuti senarai produk mereka dan bertanya sebarang soalan yang anda peduli.