Simbol |
Parameter |
Kondisi pengujian |
Min. |
- Tempel. |
Maks. |
Satuan |
|
|
V CE(sat)
|
Kolektor ke Emitor Tegangan Jenuh
|
B C =450A,V GE = 15V, T vj =25o C |
|
1.10 |
1.35 |
V
|
|
B C =450A,V GE = 15V, T vj =150o C |
|
1.10 |
|
|
B C =450A,V GE = 15V, T vj =175o C |
|
1.10 |
|
|
B C =1000A,V GE = 15V, T vj =25o C |
|
1.40 |
|
|
B C =1000A,V GE = 15V, T vj =175o C |
|
1.60 |
|
|
V GE (th) |
Ambang Gerbang-Emitor Tegangan |
B C =12.9mA ,V CE =V GE , T vj =25o C |
5.5 |
6.4 |
7.0 |
V |
|
B CES |
Kolektor Memotong -MATI Saat ini |
V CE =V CES ,V GE =0V, T vj =25o C |
|
|
1.0 |
mA |
|
B GES |
Kebocoran Gerbang-Emitor Saat ini |
V GE =V GES ,V CE =0V, T vj =25o C |
|
|
400 |
nA |
|
Batang Gint |
Resistensi Gerbang Dalam |
|
|
1.2 |
|
ω |
|
C ies |
Kapasitas input |
V CE =50V,f=100kHz, V GE =0V
|
|
66.7 |
|
nF |
|
C oes |
Kapasitansi Output |
|
1.50 |
|
nF |
|
C res |
Transfer Balik Kapasitansi |
|
0.35 |
|
nF |
|
Q G |
Biaya gerbang |
V CE =400V,I C =450A, V GE =-15…+15V |
|
4.74 |
|
μC |
|
t d (pada ) |
Waktu penundaan menyala |
V CC =400V,I C =450A,
Batang Gon = 1,2Ω, Batang Goff =1.0Ω, V GE =-8V/+15V,
L S =24nH, T vj =25o C
|
|
244 |
|
n |
|
t batang |
Waktu naik |
|
61 |
|
n |
|
t d ((off) |
Matikan Waktu tunda |
|
557 |
|
n |
|
t f |
Waktu musim gugur |
|
133 |
|
n |
|
E pada |
Nyalakan Beralih Kerugian |
|
11.0 |
|
mJ |
|
E mATI |
Switching Matikan Kerugian |
|
22.8 |
|
mJ |
|
t d (pada ) |
Waktu penundaan menyala |
V CC =400V,I C =450A,
Batang Gon = 1,2Ω, Batang Goff =1.0Ω, V GE =-8V/+15V,
L S =24nH, T vj =150o C
|
|
260 |
|
n |
|
t batang |
Waktu naik |
|
68 |
|
n |
|
t d ((off) |
Matikan Waktu tunda |
|
636 |
|
n |
|
t f |
Waktu musim gugur |
|
226 |
|
n |
|
E pada |
Nyalakan Beralih Kerugian |
|
16.9 |
|
mJ |
|
E mATI |
Switching Matikan Kerugian |
|
32.2 |
|
mJ |
|
t d (pada ) |
Waktu penundaan menyala |
V CC =400V,I C =450A,
Batang Gon = 1,2Ω, Batang Goff =1.0Ω, V GE =-8V/+15V,
L S =24nH, T vj =175o C
|
|
264 |
|
n |
|
t batang |
Waktu naik |
|
70 |
|
n |
|
t d ((off) |
Matikan Waktu tunda |
|
673 |
|
n |
|
t f |
Waktu musim gugur |
|
239 |
|
n |
|
E pada |
Nyalakan Beralih Kerugian |
|
19.2 |
|
mJ |
|
E mATI |
Switching Matikan Kerugian |
|
33.6 |
|
mJ |
|
B SC |
Data SC |
t P ≤6μs, V GE = 15V,
T vj =25o C,V CC =400V, V CEM ≤750V
|
|
4900 |
|
A |
|
|
|
t P ≤3μs, V GE = 15V,
T vj =175o C,V CC =400V, V CEM ≤750V
|
|
3800
|
|
|
|